|
Home
> Company
> Electrical Equipment & Supplies
> Others
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Our firm represents the manufacturer geophysical load-carrying armored cable in ukraine.
We offer this production -geophysical(load-carrying, self bearing) armoured cable. It is a lot of years the geophysical cable made at us the fishery companies use. So, company 'antarctica', from illichivsk fishery port, is one of our steady customers Of this cable. More than 12 years we deliver our production and we have no any complaint to its quality. We can make and supply geophysical cables the following types: - gost kg 1-55-90(standard tehnology europe - asia geophisical association 10-01) - gost kg 1-30-90(standard tehnology europe - asia geophisical association 10-01) Cables all types can be maintained in aggressive environments. Below Fundamental technical characteristics of geophysical cable gost kg 1-30-90(st eaga 10-01) - outer diameter - 6,5 mm(0,26 in) - building lenght - 1000-5000 m(3281-16400 ft) - limit of breaking strength - 30 kn(3059 kg or 6744 lb) - conductor represents a strand, which Consists of seven non-insulated copper Wires, and each of this copper wires has A diameter in cross-section - 0,37mm(0.02 in) - piece of condactors - one - cross-section area of a strand - 0,75 sq. Mm(0.0012 sq. In) - cable has two layers of an armor, And each of them consists of Galvanized high-tensile steel-wires: A) outer armor(rhl) - 13(?±1) piece; B) inner armor(lhl) - 12(?±1) piece. - insulation of a conductor is made of A polymeric material of the low pressure, Keeping working-capacity at an Environment temperature a maximum: - +90?°c(194,0?°f) - electric resistance to direct current A strand of a cable length of 1000 m(3281 ft) - 15-25 ohm - nominal test voltage, during 5 minutes under Condition of a environment temperature to +90?°c(194,0?°f) - 2000 ~v,50 herz Fundamental technical characteristics of geophysical cable gost kg 1-55-90(st eaga 10-01) - outer diameter - 9,4 mm(0,37 in) - building lenght - 1000-5000 m(3281-16400 ft) - limit of breaking strength - 55 kn(5608 kg or 12360 lb) - conductor represents a strand, which Consists of seven non-insulated copper Wires, and each of this copper wires has A diameter in cross-section - 0,37mm(0.02 in) - piece of condactors - one - cross-section area of a strand - 0,75 sq. Mm(0.0012 sq. In) - cable has two layers of an armor, And each of them consists of Galvanized high-tensile steel-wires: A) outer armor(rhl) - 17(?±1) piece; B) inner armor(lhl) - 14(?±1) piece. - insulation of a conductor is made of A polymeric material of the low pressure, Keeping working-capacity at an Environment temperature a maximum: - +90?°c(194,0?°f) - electric resistance to direct current A strand of a cable length of 1000 m(3281 ft) - 15-25 ohm - nominal test voltage, during 5 minutes under Condition of a environment temperature to +90?°c(194,0?°f) OEM Service: No. of R&D Staff: Estimated Annual Sales (USD): Export Percentage: Quality Control: Legal Representative/CEO: Factory Size (Sq.meters): Factory Location: Corporate Status:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||